Repeat Procedures Within 30 days in Patients Stented for Malignant Distal Biliary Strictures: Experience of 508 Patients at a Tertiary Referral Center
Abstract
Background: Stent related occlusion and migration remains a problem despite attempts to improve stent design over this time period. Flanged polyethylene plastic stents (FPS) remains the stent of choice in most centers. Early failure of stents placed for malignant extrahepatic biliary strictures (MEBS) has not previously been studied in detail. We set out to determine the incidence and reasons for biliary stent change within 30 days of the index procedure in a large tertiary center population during a period where (FPS) was the sole plastic stent used.
Methods: Retrospective analysis of endoscopic retrograde cholangiography (ERCP) was undertaken in patients who were stented for presumed or known MEBS between 1993 and 2001. Patients who required repeat stenting within 30 days were identified.
Results: All 508 patients were stented for MEBS. 5.7% of patients had a total of 34 repeat stenting procedures within 30 days of the index procedure; 27of 29 index stents were plastic, 2 were self-expandable metal stents (SEMS), 20 (3.9%) patients had stent failure as the reason for a stent exchange (plastic stent occlusion n = 15, mean time to stent change 14 8.3 days; metal stent occlusion n = 2, mean time to stent change 24.5 7.8 days; plastic stent migration n = 3, mean time to stent change 25 5.3 days). There was a statistically significant difference in the time to stent change between the occluded plastic stent and migrated plastic stent cases (P = 0.045, 95% CI -21.7 to -0.29). 6 patients spent at least 2 additional days in hospital as a result of stent failure.
Conclusions: Early stent failure is an uncommon problem, especially in patients with SEMS. Early plastic stent failure appears to occur sooner with stent occlusion than with stent migration. Early stent failure is associated with significant morbidity and bears an economic impact in additional procedures and hospital stay.
Gastroenterol Res. 2012;5(2):57-62
doi: https://doi.org/10.4021/gr420w
Methods: Retrospective analysis of endoscopic retrograde cholangiography (ERCP) was undertaken in patients who were stented for presumed or known MEBS between 1993 and 2001. Patients who required repeat stenting within 30 days were identified.
Results: All 508 patients were stented for MEBS. 5.7% of patients had a total of 34 repeat stenting procedures within 30 days of the index procedure; 27of 29 index stents were plastic, 2 were self-expandable metal stents (SEMS), 20 (3.9%) patients had stent failure as the reason for a stent exchange (plastic stent occlusion n = 15, mean time to stent change 14 8.3 days; metal stent occlusion n = 2, mean time to stent change 24.5 7.8 days; plastic stent migration n = 3, mean time to stent change 25 5.3 days). There was a statistically significant difference in the time to stent change between the occluded plastic stent and migrated plastic stent cases (P = 0.045, 95% CI -21.7 to -0.29). 6 patients spent at least 2 additional days in hospital as a result of stent failure.
Conclusions: Early stent failure is an uncommon problem, especially in patients with SEMS. Early plastic stent failure appears to occur sooner with stent occlusion than with stent migration. Early stent failure is associated with significant morbidity and bears an economic impact in additional procedures and hospital stay.
Gastroenterol Res. 2012;5(2):57-62
doi: https://doi.org/10.4021/gr420w
Keywords
ERCP; Bile duct stricture; Cancer